Product overview
The LMR intelligent magnetostrictive liquid level meter is a high-precision liquid level measuring instrument. The instrument works normally with large measuring range, multiple installation modes, quick commissioning and extremely high cost performance.
Product parameters
● Repeatability: Better than ±0.002%FS;
● Output temperature: 50ppm/℃;
● Product power consumption: ≤50mA;
● Output ripple: ≤20mV;
● Dead zone: Soft rod: Upper dead zone: 100mm, lower dead zone: 300mm;
● With load capacity: 4~20mA output: With load capacity≤500Ω;
●0~5V and 0~10V output: * Small controller load≥5kΩ;
● Measuring bar material: 0Cr18Ni9, 1Cr18Ni9Ti or user's specific customization;
● Electronic storehouse enclosure material: 1Cr18Ni9Ti;
● Floating ball material: 0Cr18Ni9, 316 and nitrile rubber;
● Anti-explosion type: ExdⅡBT5, ExiaⅡBT5 and ExdⅡCT5
● Protection grade: IP65
● Measuring range: Hard rod: 150mm~4000m m, soft rod: * Length: 20000mm;
● Output form: 4~20mA, 0~5V, 0~10V, ±5V, ±10V and RS-485;
● Linearity error: Better than ±0.05%FS; Sensor with measuring range being less than 300mm and error: less than 150μm;
● Hard rod: Upper dead zone: 51mm, lower dead zone: 36mm, with black line mark; (appropriate change as per use requirements)
● Installation form: Screw installation, connector installation, locating ring installation, hanging installation or user's special customization
● Lead method: Shielded cable connection, default length: 1.5 m (change pursuant to user requirements), aviation plug connection and block terminal connection;
Product model selection
LMR | Magnetostrictive liquid level meter | ||||||
Classification E Magnetostrictive liquid level meter and no site digital display W Magnetostrictive liquid level meter and site digital display | |||||||
Measurement type V Standard (rigid) rod diameter: 16mm, Maximum: 9000mm S flexible, maximum length: 25.3m | |||||||
Process temperature H0 ≤77℃ H1 ≤121℃ H2 ≤232℃ | |||||||
Option R Two liquid levels (liquid level+ position) only AT100 W with temperature transmitting output H With HART protocol | |||||||
Explosion proofing D Flame-proof type E Intrinsic safety type | |||||||
Measuring bar length *** (1000 indicates measuring bar length: 1000mm) | |||||||
Measuring range: *** (800 indicates measurement scope: 800mm) | |||||||
LMR- |