LCT capacitance level gauge
View: Pubdate:2022-04-27



Product overview 

The LCT liquid level transmitter is a radio frequency induction type liquid level instrument manufactured by development after our company introduces the technology of similar products abroad. It can convert the changes of various level parameters into standard current signals and carry out remote transmission of them to the operation control room for centralized display, alarm or automatic control of secondary instrument or computer. It's of good structure and installation way and can apply to the liquid level under special conditions (such as high temperature, high pressure, strong corrosion, easy crystallization, clogging resistance, cold condensation resistance, solid powder and granular material) and continuous detection of material level and be widely used for test and control in various industrial processes. 


Product features 

● Measuring range: Random selection and use within the scope of 300-5000mm; 

 -0.1MPa~4.0MPa; 

● Operating temperature: Rod type: -70°C~450°C; 

● Probe diameter: ¢8mm, ¢10mm, ¢16mm and ¢22mm 

● Probe material: PTFE, corundum; 

● Wet receiving material: Stainless steel; 

● Output signal: 4-20mA DC and 4-20mA overlaid HART protocol; 

● Stability: ≤0.2%FS/year; 

● High precision and strong general performance. 

● Strong practicability, key setting, one-key calibration, calibration by any two points and extremely simple operation. 

● The digital software filtering technology is used without influence of air flow and liquid level, and the fast tracking of transient changes and displaying the average effect of liquid level can be achieved with stable and accurate display. 

● The normal working can be realized under the voltage of 18-28V with safety barrier of any model met. 

● The soft/hard anti-interference and error correction technology are used, and no isolation, but direct accessing to network is adopted in the non-explosion proof place, lowering the circuit complexity and lowering the cost. 

● Applicable medium: Any medium without no corrosion to polytetrafluoroethylene (such as liquid ammonia, compressed gas, methyl alcohol, copper liquid, propylene carbonate and doctor solution) 


Product model selection 


LCT

Capacitance level gauge


Medium

F Corrosive medium      N Noncorrosive medium


Medium temperature

H High temperature W Normal temperature


Measurement form

P Cable type measuring       B Lever measurement


Precision

B 0.25%F.S      C  0.5%F.S


Installing form

1 M20×1.5 mounting thread   2 M27×2 mounting thread    3 Flange installation  4 Special installation (given by the user)


Gauge head form

M0 None       M1 Pointer table head      M2 Numeration table head


Explosion-proof way

D Intrinsic safety explosion proofing   E Isolation explosion proofing


Liquid level range

      ****  (1000 indicates liquid level range: 1000mm)

LCT-